SVF300 Series High Performance vector control frequency inverter
SVF300 series high Performance vector control frequency inverter is SEL Electrical developed the new type frequency inerter . General type and fan/pump type are in one model .
- Description
- Inquiry
1. Main Feature
SVF300 Series inverters are high performance open loop vector inverters for controlling asynchronous AC induction motors and permanent synchronous motors.
1. Output frequency :0-600Hz.
2. Multiple password protection mode
3. Remote control operation keypad, convenient for remote control.
4. V/F curve &multi-inflection point setting, flexible configuration .
5. Keyboard parameter copy function. easy to set the parameters for multi-inverters .
6. Wide industry application . to expand special function according to different industries.
7. Multiple hardware and software protection and optimized hardware for anti-interference technology.
8. Multi-step speed and wobble frequency running (external terminal 15 steps speed control).
9. Unique adaptive control technology . Auto current limiting and voltage limiting and under-voltage restrain .
10. Optimized external installation and internal structure and independent air flue design , fully enclosed electrical space design .
11. Output automatic voltage regulation function .(AVR),automatically adjust the output pulse width . to eliminate the influence of the grid change on load .
12. Built-in PID regulation function to facilitate the realization of closed loop control of the temperature ,pressure and flow . and reduce the cost of the control system .
13. Standard MODBUS communication protocol . easy to achieve the communication between PLC,IPC and other industrial equipments.
2. Technical Indications
Item | Item Description | |
Input | Rated voltage& Frequency | Single /Three phase 220VAC . Three phase 380V.50Hz/60Hz |
Allowable Voltage range | Voltage fluctuate range:-20%~+20% | |
Output | Rated voltage | three phase 0~ input AC voltage |
Frequency | 0.00~600.00Hz | |
Overload capacity | Type G:150% 1minute,180% 1 second,200% transient protection | |
Control Function | Modulation mode | Optimal space voltage vector PWM modulation |
Control mode | Sensorless vector control (SVC), V/F control . Torque control | |
Frequency accuracy | Digital setting: Max. Frequency ×±0.01% | |
Frequency resolution | Digital setting :0.01HZ; | |
Starting frequency | 0.00~10.00Hz | |
Torque lift | Automatic torque lift: To lift the torque automatically according to the output current. | |
Slip compensation | Setting range:0~150%,The inverter output frequency can be auto-regulated within this range according to the motor load, so as to reduce the speed variation of the motor due to load fluctuation. | |
Acceleration/deceleration | Minutes/Seconds can be selected as time unit .0.1~3600S can be set in sequence . | |
Carrier frequency | 1.0~15.0KHz | |
Jog function | Jog frequency range:0.01~600.00Hz, | |
V/F curve | 1:linear curve;2:quadratic;3:user defined V/F curve | |
Control Function | Automatic energy-saving operation | Auto optimize V/F curve according to the load changes to realize the energy saving operation. |
Auto voltage regulation (AVR) | When the network voltage changes, it can regulate PWM output automatically to maintain constant voltage. | |
Built-in PID | This can form a convenient closed-loop control system (CLCS)and is applicable to pressure control, flow control and other process control . | |
Operation Function | Operating command | Operation panel control ,external terminal control and COM control |
Frequency setting | Keypad potentiometer setting , operation panel▲▼setting,. external terminal UP/DOWN setting, analog voltage signal or external potentiometer setting , analog current signal setting .terminal combination setting ,485 COM setting and so on. | |
Input Signal | Forward/Reverse signal、multi-speed signal 、 fault signal 、 | |
Output signal | Programmable relay、 open collector output 、 Fault signal output. | |
Multi-function analog and digital output terminal | This can realize the output of frequency current and other physical quantity by output 0-10V or 0-20mA DC signal and 0-10KHz digital signal output. | |
Braking function | Dynamic braking | With an external braking resistor, the maximum braking torque may reach 100%. |
DC Braking | This can be selected when the motor starts or stops with the action frequency of 0-20Hz,action current level of 0-100% and actuation time of 0-30sec., which can be set in sequence. | |
Other Function | Skip frequency、Jog function、 Counter 、Rotation speed tracking、 Momentary power loss restart 、Frequency upper/lower limiting、 Acceleration/ Deceleration mode can be adjusted 、Frequency meter and Voltmeter output 、Multi-speed/ program running 、Two wire mode/ three wire mode control 、Wobble frequency control、 Multi-function input terminal selection 、 Fault auto reset、RS485 serial communication . | |
Protection Function | Input phase loss protection、 Over current protection 、Overload protection、 Over voltage protection 、Under voltage protection、 Over heat protection ect. | |
LED display | Can display the real time running status of the inverter , monitor parameter .function parameter and fault code and other information of the inverter. | |
Matching parts | Braking assembly, remote keypads and wire connection , communication panel . | |
Ambient | Place to be used | Indoor location free from direct exposure to sun light, high humidity or dew condensation, high levels of dust, corrosive gas, explosive gas, inflammable gas, oil mist, salt and etc |
Altitude | Below 1000 M | |
Ambient Temperature | -10 C to +45 C (Bare Machine: -10 C to+50 C) | |
Humidity | 20%-90% RH without dew condensation | |
Vibration | <0.5G | |
Storage temperature | -20~+60C | |
Structure | Protection class | IP20 |
Cooling mode | Forced air cooling | |
Installation mode | Wall mounted or floor-type actuator |