  • CJ19 Changeover Capacitor ContactorCJ19 Changeover Capacitor Contactor

    CJ19 Changeover Capacitor Contactor

    CJ19 series changeover contactor (hereinafter referred to as contactor) is mainly used for AC 50 Hz (or 60 Hz) and rated operation In the power line with voltage up to 690V.

  • CJX1 (3TF)contactor2

    CJX1 AC Contactors

    CJX1 < 3tf > electrical magetic contactor products are AC 50 Hz or 60 Hz. The magetic contactor rated insulation voltage is 690-1000v. Under the category of AC3, when the rated working voltage is 380V, the magnetic contactor rated working current is 9A-400A. The AC contactor is mainly used for remote connecting and breaking circuit.The electrical magetic contactor is suitable for controlling the starting of AC motor. Stop and reverse, The Contactor is in line with IEC947, VDE0660, GB14048 and other standards

  • CJX2 AC Contactors

    CJX2 series AC contactors (hereinafter referred to as Contactors) are mainly used for AC 50 Hz (or 60 Hz), rated working voltage to 690 V, rated working current to 95 A under AC-3, 400 (380) V use category, For remote connection and breaking circuit, frequent starting and control of AC motor, and can form electromagnetic starter with appropriate thermal relay to protect possible operation Overload circuit.

    The  contactors Conform to GB / T 14048.4 and IEC / en 60947-4-1.

  • CJX2-F AC contactor

    CJX2-F AC electrical contactor

    CJX2-F AC electrical contactor is suitable for the circuit of AC 50 Hz or 60 Hz, voltage to 660 V and current from 115 A to 1000 a, which is used for remote connection and breaking circuit, frequent starting and control of AC motor. In addition, CJX2-F AC electrical contactor can be equipped with auxiliary contact group, air delay head, mechanical interlock and other accessories to form delay contactor, reversible contactor, star delta starter, and can be directly installed with thermal relay to form electromagnetic starter to protect overload circuit.

  • CJX2-K(LC1-K) mini contactor

    CJX2-K(LC1-K)  mini contactor is suitable for circuit and frequent starting speed to control AC motor. Adding contactor auxiliary contact group, living with appropriate thermal relay, can take action to protect circuit overload. It conforms to iec60947-4-1.

  • CJX2N Mechanical Interlocking Contactor(reversible contactor)

    CJX2-N Mechanical Interlocking Contactor(reversible contactor)

    CJX2-N reversible contactor is mainly used for AC 50 Hz, rated insulation voltage to 1000 V, rated working current to 95 a line, to control the forward and reverse rotation of AC motor.

    The reversible contactor composed of two CJX2 Contactor is interlocked by mechanical interlocking mechanism to ensure that the two contactors can not be pulled in at the same time and the normal forward and reverse rotation of AC motor; the mechanical interlocking mechanism has no effect on the action time of single AC contactor

  • CJX2-ZCJX2-Z

    CJX2-Z AC Contactors

    CJX2-Z series DC operated AC contactor is suitable for use in the circuits up to rated voltage660V AC 50Hz or 60Hz, and in rated current 9-95A in AC-3/380V load circuits. For remotecontrolling circuit making, breaking and frequent starting AC motors. It can also combine withthe auxiliary contact group, air delayer, thermal relay devices etc.

  • CJX2N AC magnetic contactor

    CJX2N AC magnetic contactor (hereinafter referred to as Contactors) are mainly used for AC 50 Hz or 60 Hz rated voltage to 690 V and rated working current to 95 A under AC-3 usage category.  The  magnetic contactor   are mainly used for frequently starting and controlling AC motor .
    According to the standard: GB / T 14048.1/iec 60947-1, GB / T 14048.4/IEC 60947-4-1.

  • DS7 Star-delta StarterDS7 Star-delta Starter

    DS7 Star-delta Starter

    DS7 Star-delta Starter

  • Electromagnetic RelayElectromagnetic Relay

    Electromagnetic Relay

    Electromagnetic Relay

  • JR28 Series Thermal RelayJR28 Series Thermal Relay

    JR28 Series Thermal Relay

    JR28 series thermal overload relay (hereinafter referred to as thermal relay) is suitable for overload and open phase protection of AC motor with AC 50 Hz / 60 Hz, voltage to 690 V and current of 0.1-630A for long or intermittent operation.
    The thermal relay also has the functions of temperature compensation, action indication, automatic manual reset, stop and so on. The product performance is stable and reliable.
    The thermal relay meets the requirements of GB 14048.4, GB 14048.5, IEC 60947-4-1, etc.
    The thermal relay can be connected with the contactor or installed independently

  • JRS2 Series Thermal RelayJRS2 Series Thermal Relay

    JRS2(3UA) Series Thermal Relay

    JRS2 (3UA) series thermal relay (bimetallic thermal overload relay)is suitable for AC 50 / 60Hz, voltage to 660-1000v, current to 630A long-term work or intermittent long-term work. thermal relay is generally used as motor thermal overload protection, with open phase protection, temperature compensation, trip indication function, automatic and manual reset, and can be connected with contactor.  It can also be installed independently.