SL360-63A Residual Current Circuit Breaker
SL360-63A residual current operated circuit breaker (residual current breaker) is suitable for AC 50 Hz, rated voltage two pole 240V, four pole 415V, rated current up to 63A line.
- Description
- Additional Information
- Inquiry
SL360-63A residual current operated circuit breaker (residual current breaker) is suitable for AC 50 Hz, rated voltage two pole 240V, four pole 415V, rated current up to 63A line.SL360-63A residual current operated circuit breaker (residual current breaker) is mainly used for indirect contact protection of people in distribution lines, and SL360-63A residual current operated circuit breaker (residual current breaker) can also be used to protect against fire hazards caused by grounding fault current.
SL360-63A residual current breaker (RCCB) Scope of application
SL360-63A residual current breaker (RCCB) are suitable for industrial, commercial, high-rise and residential buildings.
1.Protection against the effects of sinusoidal alternating earth fault currents
2.Protection against indirect contacts and additional protection against direct contacts
3.Protection against fire hazard caused by insulation faults
4.Controlling and Switching
5. Used in residential building, non-residential building, energy sources, industry Used in residential building, non-residential building, energy sources, industry
SL360-63A residual current breaker (RCCB) Specification
Type | Standard | IEC/EN 61008-1 | ||
Electrical features | Leakage type | Electromagnetic type | ||
Rated current In | A | 16, 25, 32,40, 50, 63, 80,100 | ||
Type (wave form of the earth leakage sensed) | A, AC | |||
Poles | P | 2,4 | ||
Rated voltage Ue | V | 240/415 | ||
Insulation voltage Ui | V | 500 | ||
Rated frequency | Hz | 50/60 | ||
Rated breaking capacity Inc=I△c | A | 4500,6000 | ||
SCPD fuse | A | 6000 | ||
Rated impulse withstand voltage (1.2/50) Uimp | V | 6000 | ||
Dielectric test voltage at ind. Freq, for lmin | kV | 2.5 | ||
Rated sensitivity I?n | A | 0.03, 0.1, 03 | ||
Rated residual making and breaking capacity I△m | A | 500(In<40A); 630(In >40A) | ||
Pollution degree | 2 | |||
Mechanical features | Electrical life | t | 4000 | |
Mechanical life | t | 8000 | ||
Protection degree | IP20 | |||
Storage temperature | °C | ・25~+70 | ||
Ambient temperature (with daily averages35°C) | °C | -5-+40 | ||
Installation | Terminal connection type | Cable/U-type bar/Pin-type busbar | ||
Terminal size top / bottom for cable | mm2 | 25 | ||
AWG | 18-3 | |||
Terminal size top / bottom for busbar | mm2 | 25 | ||
AWG | 18-3 | |||
Tightening torque | N*m | 2.5 | ||
In-Ibs | 18 | |||
Mounting | On DIN rail EN 60715(35mm)by means of fast clip device | |||
Connection | From top and bottom |