SL10L-40 Residual Current Circuit Breaker with overcurrent protection (RCBO)
SL10L-40 Residual Current Circuit Breaker with overcurrent protection (RCBO) have rated working voltage of 230V, rated working current of 40A, and rated short-circuit breaking capacity of 4.5ka/6ka.
- Description
- Inquiry
SL10L-40 Residual Current Circuit Breaker with overcurrent protection (RCBO) have rated working voltage of 230V, rated working current of 40A, and rated short-circuit breaking capacity of 4.5ka/6ka.
SL10L-40 Residual Current Circuit Breaker with overcurrent protection (RCBO) is applicable to the line with AC 50 / 60Hz, rated voltage of 230V and rated current of 40A. It can be used as overload, short circuit and leakage protection, and can also be used as a switch to connect and disconnect the line.The SL10L-40 Residual Current Circuit Breaker with overcurrent protection (RCBO) is widely used in low-voltage terminal power distribution places such as industrial and commercial buildings and civil houses
SL10L-40 Residual Current Circuit Breaker |
1. Protection against overload and short-circuit currents
2. Protection against the effects of sinusoidal alternating earth fault currents
3. Protection against indirect contacts and additional protection against direct contacts.
4. Protection against fire hazard caused by insulation faults
5. Used in residential building
6. According to the type of instantaneous release classified as follows: type B(3-5)ln, type C(5-10)ln
SL10L-40 Residual Current Circuit Breaker Specifications |
Type | Standard | lEC/EN 61009-1 | |||||||
Electrical features | Leakage type | Electromagnetic type | |||||||
Rated current In | A | 6, 10, 16, 20, 25, 32, 40 | |||||||
Type (wave form of the earth leakage sensed) | A, AC | ||||||||
Poles | P | 1P+N | |||||||
Rated voltage Ue | V | 230 | |||||||
Insulation voltage Ui | V | 500 | |||||||
Rated frequency | Hz | 50/60 | |||||||
Rated breaking capacity Icn | A | 6000 | |||||||
Rated impulse withstand voltage (1.2/50) Uimp | V | 4000 | |||||||
Dielectric test voltage at ind. Freq. for 1min | kV | 2 | |||||||
Rated sensitivity IΔn | A | 0.03, 0.05, 0.1 | |||||||
Break time under IΔn | s | ≤0.1 | |||||||
Rated residual making and breaking capacity IΔm | A | 500 | |||||||
Pollution degree | 2 | ||||||||
Mechanical features | Electrical life | t | 4000 | ||||||
Mechanical life | t | 8000 | |||||||
Protection degree | IP20 | ||||||||
Storage temperature | ℃ | -25~+70 | |||||||
Ambient temperature (with daily average≤35℃) | ℃ | -5~+40 | |||||||
Installation | Terminal connection type | Cable/U-type bar/Pin-type busbar | |||||||
Terminal size top / bottom for cable | mm² | 16 | |||||||
AWG | 18-5 | ||||||||
Terminal size top / bottom for busbar | mm² | 16 | |||||||
AWG | 18-5 | ||||||||
Tightening torque | N*m | 1.2 | |||||||
In-Ibs | 11 | ||||||||
Mounting | On DIN rail EN 60715(35mm)by means of fast clip device | ||||||||
Connection From top and bottom |